BRAND REPORT · 2026 AUTUMN
Texture
Analyzer
Texture Profile Analysis Special · October 2026 Autumn Issue
Issue date: October 2026 [TBD: issue day]
October
Purchase Offer
[TBD] October offer details, dates and terms — to be provided by sales.

Featured Product
RapidTA+
More stable, more precise — the advanced RapidTA!
A high-sensitivity transducer for gels, cosmetics, and other precision samples with advanced QC needs.
View RapidTA+ specifications and applications →Recommended Test Samples
Select a sample to see its recommended methods and probes.
Common Test Methods
Principle, probe selection, data interpretation and FAQs are on each test action page.
TPA (Texture Profile Analysis)
One test returns hardness, springiness, cohesiveness and more — simulating human chewing.
Learn more →
Puncture Test
Measures puncture resistance — surface hardness, fracturability and gel strength.
Learn more →
Compression Test
Measures mechanical response under compressive load — for hardness and springiness.
Learn more →
Adhesion Test
Measures the peak force to separate a probe from the sample surface — rating stickiness.
Learn more →
Cutting / Shear Test
Mimics teeth cutting through food — measures maximum shear force and fracture behavior.
Learn more →
Tension / Extensibility Test
Pulls the sample vertically to measure extension and breaking force — extensibility and tensile strength.
Learn more →
Specifications
RapidTA Series Comparison
| Model | RapidTA | RapidTA HD | RapidTA+ | RapidTA MAX |
|---|---|---|---|---|
| Load cell (interchangeable) | 500 / 1,000 / 5,000 / 10,000 / 20,000 gf | 500 / 1,000 / 5,000 / 10,000 / 20,000 / 50,000 gf | 500 / 1,000 / 5,000 / 10,000 / 20,000 gf | 500 / 1,000 / 5,000 / 10,000 / 20,000 / 50,000 gf |
| Force range | 500 – 20,000 gf | 500 – 50,000 gf | 500 – 20,000 gf | 500 – 50,000 gf |
| Force resolution | 0.1 gf | 0.1 gf | 0.1 gf | 0.1 gf |
| Force accuracy | reading 0.5% < error < full range 1% | reading 0.5% < error < full range 1% | reading 0.5% < error < full range 1% | reading 0.5% < error < full range 1% |
| Stroke | 100 mm | 100 mm | 200 mm | 350 mm |
| Distance resolution | 0.001 mm | 0.001 mm | 0.001 mm | 0.001 mm |
| Distance accuracy | 0.1 % | 0.1 % | 0.1 % | 0.1 % |
| Speed range | 0.025 – 10 mm/s | 0.025 – 10 mm/s | 0.025 – 10 mm/s | 0.025 – 10 mm/s |
| Speed resolution | 0.025 mm/s | 0.025 mm/s | 0.025 mm/s | 0.025 mm/s |
| Speed accuracy | 0.1 % | 0.1 % | 0.1 % | 0.1 % |
| Data acquisition rate | Up to 2000 points per second | Up to 2000 points per second | Up to 2000 points per second | Up to 2000 points per second |
| Size | 210 × 290 × 550 mm | 250 × 200 × 630 mm | 225 × 300 × 520 mm | 300 × 400 × 620 mm |
| Net weight | 8.2 kg | 15.5 kg | 10.5 kg | 14.1 kg |
| Power supply | 100–240 V 50/60 Hz | 100–240 V 50/60 Hz | 100–240 V 50/60 Hz | 100–240 V 50/60 Hz |
| Power consumption | 25 W | 30 W | 15 W | 20 W |
| Limit switches | Electromagnetic | Electromagnetic | Optical | Optical |
| Protection | Emergency stop, force overload protection | Emergency stop, force overload protection | Emergency stop, force overload protection | Emergency stop, force overload protection |
| Software | White collar (WC) / Blue collar (BC) | White collar (WC) / Blue collar (BC) | White collar (WC) / Blue collar (BC) | White collar (WC) / Blue collar (BC) |
| Baud rate | RS-232 460800 | RS-232 460800 | RS-232 460800 | RS-232 460800 |
Resources
Tutorial Videos
Step-by-step videos from start-up and software setup through testing and data export.
Open the playlist →Application Guide
Find the operating steps and application notes for each test sample and test method.
Open the Application Guide →Not sure which texture test method fits your product?
Feel free to share your testing needs anytime — we provide free test method recommendations, custom fixture selection, instrument model suggestions, and tailored quotes.